Case: T09DV06514

Parcel: 111070760


Addresses:

3402 E FLOWER ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
11/04/2009 INSP - INITIAL CODE ENFORCMENT Approved VANS INSPECTION CONDUCTED; UNABLE TO CONDUCT INTERIOR INSPECTION; PROPERTY AT ADDRESS IS VACANT, WITH BOARDED WINDOWS; WINDOWS CONFIRMED BOARDED 8/22/08 PER PREVIOUS CASE INSPECTIONS (SEE T08DV05481). YARD AREA IS CLEAN; MAIN STRUCTURE HAS DILAPIDATED ROOF OVERHANG AND FASCIA ALONG ALL SIDES INDICATING A PROBLEM WITH WATER DAMAGE AND THE ROOF. FRONT PORCH CEILING HAS BEEN REMOVED, EXPOSING RAFTERS AND ROOF INTERIOR; WATER DAMAGE IS PRESENT; THIS ALSO EXPOSES THE ATTIC TO PESTS. ELECTRIC SWITCH AND OUTLET HAVE BEEN ADDED TO REAR EXTERIOR WALL AND ARE NOT CORRECTLY RATED FOR EXTERIOR (NON GFCI). WATER HEATER IS LOCATED OUTSIDE IN A DILAPIDATED CONDITION; HPRV APPEAR CONNECTED TO HOT WATER OUTFLOW; HEATER IS NOT COVERED AND IS EXPOSED TO ELEMENTS. PREVIOUS CASE T08DV05481 MENTIONED THAT INTERIOR HAS BEEN STRIPED OF COPPER WIRING AND DRY WALL. EXTERIOR SIDING APPEARS TO HAVE BEEN ADDED AT SOME POINT, BUT PORTIONS ARE NOT COVERED; ORIGINAL WALLS APPEAR DILAPIDATED. SHED ON PROPERTY HAS WHAT APPEARS TO BE ILLEGAL CIRCUITS ADDED AND IS DILAPIDATED ON THE INTERIOR. LRP