Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T09DV05068
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2009 | INSP - INITIAL CODE ENFORCMENT | Approved | RESEARCH COMPLETED, BUILDING IS BEING OCCUPIED WITHOUT A CERTIFICATE OF OCCUPANCY BUSINESS BATTERY OUTLET OPEN TO THE PUBLIC NO APPROVED SITE PLAN FOR THE USE OF LAND. PROPERTY IS BEING USE TO STORE OVER 100 PALLETS OF LEAD ACID BATTERIES ( OUTDOOR STORAGE ) ZONE IS C-2" COMMERCIAL ZONE NEW ADDED CIRCUITS INSTALLED IN THE INTERIOR AND EXTERIOR OF THE BUILDING. THE INTERIOR CIRCUIT IS SUPPLYING POWER TO A SERIES OF JUNCTION BOXES. THE RACEWAY RUNS FROM THE PANEL BOARD IN CONDUIT AND RUNS ACROSS THE CEILING OF THE GARAGE TO A SERIES OF FOUR JUNCTION BOXES ATTACHED THE INTERIOR OF THE BUILDING. THE EXTERIOR CIRCUIT IS SUPPLYING POWER TO A JUNCTION BOX UNDERNEATH THE CARPORT OF THE BUILDING. THE RACEWAY IS ARMORED CABLE THAT RUNS ON TOP OF THE METAL SHEATHING OF THE CARPORT TO THE JUNCTION BOX ATTACHED TO THE POLE OF THE CARPORT. ACCESS TO THE SERVICE EQUIPMENT MAIN DISCONNECT LOCATED REAR OF THE BUILDING IS BEING BLOCKED BY PALLETS OF BATTERIES INTERIOR PANEL BOARD DOES NOT HAVE APPROPRIATE PANEL SCHEDULED. |
|
09/04/2009 | INSP - INITIAL CODE ENFORCMENT | Approved | ON SITE INSPECTION OF THE BATTERY OUTLET BUSINESS THE BUILDING IS BEING OCCUPIED WITHOUT A CERTIFICATE OF OCCUPANCY. THE BUSINESS IS IN C-2" COMMERCIAL ZONE. RESEARCH RECORDS AT DSD AND FOUND NO APPROVED SITE PLAN FOR THE CURRENT BATTERY OUTLET BUSINESS NEW ADDED CIRCUITS INSTALLED IN THE INTERIOR AND EXTERIOR OF THE BUILDING. THE INTERIOR CIRCUIT IS SUPPLYING POWER TO A SERIES OF JUNCTION BOXES. THE EXTERIOR CIRCUIT IS SUPPLYING POWER TO A JUNCTION BOX UNDERNEATH THE CARPORT OF THE BUILDING. THE MAIN DISCONNECT IS BEING BLOCKED WITH PALLETS OF BATTERIES NO ACCESS. INTERIOR PANEL BOARD DOES NOT HAVE APPROPRIATE PANEL SCHEDULED. AT REAR OF THE BUSINESS PROPERTY THERE IS A DWELLING, THERE IS NO WALL SEPARATION BETWEEN THE COMMERCIAL ZONE AND THE RESIDENTIAL USE. THERE IS A CHAIN LINK FENCE AT THE LOT LINE BETWEEN PROPERTIES. THERE ARE OVER ONE HUNDRED PALLETS OF BATTERIES BEING STORED AT THE REAR OF THE BUILDING BETWEEN THE BUILDING FACE AND THE LOT LINE. |
|
08/28/2009 | INSP - INITIAL CODE ENFORCMENT | Approved | PEDDLER CITED FOR OPERATING WITH EXPIRED LICENSE, NOTICE WAS GIVEN AND SHUT THE BUSINESS DOWN. WILL RESEARCH PROPERTY AT DSD FOR SITE PLAN APPROVALS |