Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T09DV04159

Parcel: 124052290


Addresses:

912 E 6TH ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T09DV04159

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
08/14/2009 INSP - INITIAL CODE ENFORCMENT Approved NEW 11X 23 ATTACHED WOOD FRAMED ADDITION
THE ADDITION IS ATTACHED TO THE REAR OF THE DWELLING. THE ADDITION IS DIVIDED INTO TWO LAUNDRY ROOMS.

NEW AIR CONDITIONING UNITS
TWO NEW A/C CONDENSERS ON THE ROOF OF THE ADDITION. DEAD LOAD CALCULATION REQUIRED DUE TO ADDITIONAL WEIGHT ON ROOF. ROOF RAFTERS ARE 2 X 4'S

NEW ELECTRICAL EQUIPMENT
THE ADDITION HAS NEW ELECTRICAL
JUNCTION BOXES, FOR THE DRYER, WASHER, WALL OUTLET AND A/C UNITS

NEW CONDUIT FROM PANEL BOARDS ADDITION, ROOF TOP AND ENTER THE DWELLING DESTINATION UNKNOWN.

EXPOSED NONMETALLIC SHEATHED CABLE UNDER 96 INCHES CEILING AREA.

PANEL BOARDS MISSING BLACK COVER

NO PANEL SCHEDULED ON SERVICE EQUIPMENT


NEW EXTERIOR LIGHT INSTALLED WITH UNDERGROUND CONDUIT.

NEW PLUMBING EQUIPMENT
NEW COPPER WATER SUPPLY LINES FOR THE WASHER.

NEW ABS VENTING AND DRAIN PIPE INSTALLED

A/C CONDENSATION LINE IS DRAINING INSIDE THE ABS VENT PIPE LOCATION ON TOP OF THE ROOF.

NO PERMITS, RECORDS OR APPROVALS FOR THE CONSTRUCTION OF THE WOOD FRAMED ADDITION TO INCLUDE ALL ELECTRICAL PLUMBING AND THE INSTALLATION OF THE AIR CONDITIONING UNITS AT DEVELOPMENT SERVICE DEPARTMENT CITY OF TUCSON