Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T09DV04012
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/28/2009 | INSP - INITIAL CODE ENFORCMENT | Approved | ELECTRICAL NONMETALLIC SHEATHED CABLE HAS BEEN SPLICED INTO THE KNOB AND TUBE WIRING SYSTEM IN THE BASEMENT AREA. ADDED CIRCUITS INSTALLED WITHOUT APPROVALS AND PERMITS IN THE BASEMENT AREA. JUNCTION BOXES IN THE BASEMENT AREA WITH NO COVER PLATES, UNSECURED WIRINGS. ____________________________________ GAS WATER HEATERS INAPPROPRIATE INSTALLATION OF THE VENT CONNECTOR FOR BOTH GAS WATER HEATERS LOCATED IN THE INTERIOR OF THE DWELLING'S COMMON AREA, NO SLOPE AND TERMINATES INSIDE CHIMNEY/ CHASE. DISCHARGE PIPE FOR BOTH UNITS INAPPROPRIATE INSTALLED ONE UNIT HAS DISCHARGE PIPE WITH THREADED CONNECTION AT THE END OF THE PIPE. SECOND UNIT HAS DISCHARGE PIPE WHICH DRAINS INTO A SINK, CAN CAUSE PERSONAL INJURY |