Permit: T09CM03423

Parcel: 110081610


Addresses:

4633 E BERMUDA ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/01/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
03/30/2010 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/30/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) MUST BE 10 POUNDS-IS AT 6
2) REMOVE MESH STAPLES AT HOMERUNS AND REPLACE DAMAGED WIRING
3) DWV TEST IS EMPTY-REDO
4) NEED FULL WATER PRESSURE ON LINES
5) FIRE BLOCK DRYER VENT STUD BAY
6) STUD SHOE ALL STUDS THAT ARE OVER BORED/NOTCHED IN REAR GARAGE SHEARWALL
7) NEED NUTS ON HOLDOWNS
8) REDO GAS TEST
9) FIREBLOCK A/C LINE STUD BAY
10) INSTALL BACKFLOW PREVENTERS ON HOSE BIBS
11) STOPPED INSPECTION AFTER GARAGE, LAUNDRY AND S.E. BEDROOM