Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T09CM03415
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/22/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CLOSET FLANGES TO BE SECURED TO THE FLOOR |
|
03/12/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CORRECTIONS MADE OK 2) NEED TO SEE CLOSET FLANGES |
|
02/22/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SWEEP REQUIRED AT VERTICAL TO HORIZONTAL CHANGE OF WASTE LINE AT LAVITORS RE---- CO IF NEEDED. SUPPORT DRAIN PIPE. INSTALL FHA STEPS WHERE CI IS W/IN 1 1/4 OF STUD FACE PER COT CODE AMENDMENTS INSTALL BACKING AT MS FAUCET FOR PAUL HOOK BRACKET, OFFSET VENT IF NEEDED REMOVE EXCESS FWX FRAU COPPER JOINTS OK TO INSULATE HW---PIPING. FLOOW PLAN DETAIL BY PROVIDING OVER 250 HANGERS W/CONTINUOUS INSULATION NOTICE DETAIL FOR TRAP PRIMER, WILL INSP AT FINAL OK TO COURSE KITCHEN NORTH AND WEST WALLS AFTER INSTALLING PIPE INSULATION. LAV CARRIOE SPECIFIED. |