Permit: T09CM03415

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/13/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/22/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CLOSET FLANGES TO BE SECURED TO THE FLOOR
03/12/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) NEED TO SEE CLOSET FLANGES
02/22/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SWEEP REQUIRED AT VERTICAL TO HORIZONTAL CHANGE OF WASTE LINE AT LAVITORS RE---- CO IF NEEDED. SUPPORT DRAIN PIPE.
INSTALL FHA STEPS WHERE CI IS W/IN 1 1/4 OF STUD FACE PER COT CODE AMENDMENTS
INSTALL BACKING AT MS FAUCET FOR PAUL HOOK BRACKET, OFFSET VENT IF NEEDED
REMOVE EXCESS FWX FRAU COPPER JOINTS
OK TO INSULATE HW---PIPING. FLOOW PLAN DETAIL BY PROVIDING OVER 250 HANGERS W/CONTINUOUS INSULATION
NOTICE DETAIL FOR TRAP PRIMER, WILL INSP AT FINAL
OK TO COURSE KITCHEN NORTH AND WEST WALLS AFTER INSTALLING PIPE INSULATION.
LAV CARRIOE SPECIFIED.