Permit: T09CM03415

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/05/2010 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) OK TO COVER UP
2) OK FOR CONCRETE AFTER PIPE WRAPS
02/03/2010 PLUMBING - ROUGH, SOIL Not ready for Inspection 1) A DBL WYE, OR DBL COMBO MAY NOT BE INSTALLED IN THE HORIZONTAL POSITION
2) HORIZONTAL VENTING BELOW THE FLOOD RIM NOT PERMITTED UNLESS THERE ARE STRUCTURAL CONDITIONS
3) N/H BANDS PERMITTED FOR CAST IRON-USE APPROVED COUPLING FOR NHX51
4) BACK PITCHED SECTIONS NOT APPROVED