Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/08/2010 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/24/2010 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/14/2010 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/30/2010 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 04/28/2010 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* THIS CALL IS FOR SERVICE INCREASE: 1) 2 GROUND RODS MINIMUM 6' APART MINIMUM 2) BRACE REQUIRED AT RISER IF OVER 30" ABOVE PARAPET 3) GFI OUT LET REQUIRED AT SERVICE PANEL FOR TEMP SERVICE 4) ELECTRIC METER AND HIGHEST BREAKER SHALL NOT BE OVER 6'-6" FROM GRADE |