Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM03326

Parcel: 105096600

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM03326

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/23/2010 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/22/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/18/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OSB TO ALL STUDS IN REAR GARAGE SHEARWALL
2) SHIM NORTH TRIMMERS UNDER INTERIOR MAIN ENTRY GLUE LAM
3) NAIL OFF RSP4'S AT TOP OF EAST GARAGE WALL AND RSP4 BOTTOM OF N.E. CORNER OF HOUSE
4) BANG PLATE BOTTOM PLATE EXTERIORS AT PLUMBING