Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - PROGRESS
Permit Number - T09CM03272
Inspection Description - BUILDING - PROGRESS
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/23/2010 | BUILDING - PROGRESS | Approved | IVRS - Inspection :* 1) RECEIVED CHECK #91-567/1221 FOR $75.00 |
|
| 11/16/2010 | BUILDING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE MEANS OF DISCONNECT AT SERVICE |
|
| 06/25/2010 | BUILDING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTES 1, 4, 7 & 8 FROM PREVIOUS 2) NEW BEDROOM WINDOW EGRESS BLOCKED BY EVAPORATIVE COOLER NOT SAFE EGRESS TO PUBLIC WAY 3) PROVIDE WORKING SMOKE ALARM-HALLWAY 3) WORK TO SERVICE EQUIPMENT, NOT TO CODE 4) PROVIDE ACCESS TO EQUIPMENT FOR INSPECTION |
|
| 04/29/2010 | BUILDING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) LIGHT FIXTURE IN FURNACE ROOM COVER PLATE, TO CLOSE TO CEILING 2) HAVE QUALIFIED ELECTRICIAN CLEAN UP WIRING IN LAUNDRY-SUB PANELS 3) NEED IRON PIPE NIPPLE AT FURNACE CABINET, FLEX NOT TO ENTER CABINET 4) REMOVE ALL TAPE FROM SINGLE TO DBL WALL FLUES 3 SCREWS TO JOIN B-TYPE TO SINGLE WALL 5) ALL THREE HOLE WALL RECEPTS TO BE ON A GROUNDED SYSTEM, OR REPLACE WITH 2 HOLE, OR GFCI 6) T & P LINE TO BE A GRAVITY DRAIN, NOT TO TRAP H20 7) BATHROOM GFCI REQUIRED 8) SERVICE EQUIPMENT, HAVE ELECTRICIAN CHECK OUT WIRING FUSING AND DISCONNECTING MEANS |