Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T09CM03263
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2010 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/09/2010 | FRAMING | Denied | IVRS - Inspection : 1. PROVIDE ACCESS TO ATTIC 2. EXPOSE FOOTERS TO VERIFY DEPTH 3. EXPOSE DOUBLE TOP PLATES @ LOAD BEARING WALL 4. EXPOSE REBAR @ COLUMNS TO VERIFY 2 #4 BARS 5. RESUBMIT ACCURATE SITE PLAN - REAR STRUCTURES ON PROPERTY LINE. SHOW ADDED BATH @ UNIT 2, SHOW CARPORT UNIT 2 WITHIN 36" OF PROPERTY LINE. 6. SHOW ELECTRICAL ON PLAN 7. PROVIDE DETAILS ON ATTACHMENT TO EXISTING UNITS |