Permit: T09CM03212

Parcel: 12315294A


Addresses:

1649 N MOUNTAIN AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/05/2010 FRAMING Approved IVRS - Inspection :*
04/01/2010 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TRIPPLE JACK STUDS OVER WEST WINDOW IN 1ST FLOOR S.W. BEDROOM-UNDER TRIPLE GIRDER TRUSS
2) REPAIR FIRE BLOCK AT DRYER VENT