Permit: T09CM03180

Parcel: 133110180


Addresses:

7151 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: FIRE - FINAL

Permit Number - T09CM03180

Inspection Description - FIRE - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/13/2012 FIRE - FINAL Approved
07/18/2012 FIRE - FINAL Denied 1. DOOR IS NOT ABLE TO BE LOCKED IN ITS CURRENT STATE.
07/09/2012 FIRE - FINAL Cancelled IVRS - RI canceled
06/05/2012 FIRE - FINAL Denied In the approved plans occupant load of 28 is showing in the staging area, but load exiting out of Lowes main building was not calculated in so need to show the occupant load from main building into staging area both staging and main exiting might total over 49 therefore will need two exits out of staging area. Large swing gates on eastside do not meet man gate requirements as they will be locked to keep public from getting in need to remove exit signs from gates. Can not hamper the approved exiting requirements for the two preexisting exit doors from the Lowes building.