Permit: T09CM03152

Parcel: 114460710


Addresses:

7272 E ONDA CI

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/22/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
02/12/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONTRACTOR TO PAY REINSPECTION FEE PRIOR TO FINAL INSPECTION
2) SPOKE TO DENA AT ARS WAS TOLD REPRESENTATIVE WOULD BE HERE IN 15 MINUTES-NO SHOW
3) INSTALL PER APPROVED PLAN, PROVIDE INFORMATION ABOUT GREEN NON TOXIC PROPYLENE GLYCOL USED AS ANTI FREEZING
4) CULLEN WITH ARS MET WITH ME ON MY WAY OUT WE WENT OVER REQUIREMENTS
02/09/2010 PLUMBING - INTERMEDIATE Cancelled CANCELLED PER RITA OF RUSSETT SERVICE CORP. #622-4782
02/09/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER CONTRACTOR
02/08/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER HAL AT 631-0132
01/25/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HAVE YOUR APPROVED PLAN OF THIS INSTALLATION ON SITE FOR NEXT INSPECTION
2) YOU WILL BE CHARGED A REINSPECTION FEE PRIOR TO FINAL
3) COMPLETE NOTE #2 (LAUNDRY AREA)
4) HAVE YOUR REPRESENTATIVE ON SITE FOR NEXT INSPECTION, WHAT IS THE ANTI FREEZING SOLUTION FOR NON DRAIN BACK
12/16/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER TEMPERATURE AND PRESSURE RELIEF DRAIN TO GRAVITY DRAIN TO DAYLIGHT (NO FLEXES)
2) INSULATE THE DRAIN BACK TUBING THAT COULD BURN PEOPLE IN TOUCHABLE AREAS
3) SECURE THE TUBING PROPERLY, THE NAIL TYPE J-HOOKS DON'T HOLD IN SHEETROCK (AT CURRENT INTERVALS FOR PEX TYPE MATERIAL
4) SUPPORT TUBING AND SOLAR PANEL MINIMUM 1 1/2" UP OFF OF ROOF SURFACE AT CORRECT INTERVALS
5) PATCH ALL HOLES FROM J-HOOKS DRIVEN INTO ROOF SURFACE
6) SHOULDN'T THE DRAIN BACK SYSTEM GRAVITY DRAIN BACK TO THE DRAIN BACK TANK ?