Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) FLANGE OK |
|
| 01/04/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE CLOSET FLANGE THRU TO SUB FLOOR WITH WATER RESISTANT FASTENERS |
|
| 12/15/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 12/14/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 12/11/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. NOT INSTALLED PER PLAN 2. NO REDLINES ON SITE 3. MAY NOT DUMP A DRAIN INTO A VENT 4. SUPPORT ALL HORIZONTAL PIPE 5. SUPPORT ALL VERTICAL PIPE 6. TIE-WIRE NOT APPROVED STRAP 7. SUPPORT ALL STUB OUTS 8. TEST ALL NEW PIPE 9. SOFT SOLDER NOT PERMITTED UNDER SLAB 10. MAY NOT BE A COMPLETE LIST. |