Date Description Inspector Results Comments
02/02/2010 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/26/2010 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN AND WRAP
01/21/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DETAIL 1/SD3 BOXES FOR SHEAR TRANSFER TO HAVE BOUNDRY NAILING 4 SIDES, NAIL TO ROOGF DECK
2) X BRACE TRUSS FRONT BACK
3) ALL HEADERS SOUTH SIDE TO BE 2 X 10
4) MISSING WIND BRACE REAR WALL
5) FRONT HIP SHEETS OSB RUN LING WAY NAIL OFF 4'-0" EDGE
6) FRONT TALL GABLE FLAT STUDS, ADD ?
7) NAIL OSB TO ALL FRIEZE BOARDS
8) MISSED 4' JOINT ROOF NAIL GARAGE