Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T09CM03044
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/26/2010 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY IN AND WRAP |
|
| 01/21/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DETAIL 1/SD3 BOXES FOR SHEAR TRANSFER TO HAVE BOUNDRY NAILING 4 SIDES, NAIL TO ROOGF DECK 2) X BRACE TRUSS FRONT BACK 3) ALL HEADERS SOUTH SIDE TO BE 2 X 10 4) MISSING WIND BRACE REAR WALL 5) FRONT HIP SHEETS OSB RUN LING WAY NAIL OFF 4'-0" EDGE 6) FRONT TALL GABLE FLAT STUDS, ADD ? 7) NAIL OSB TO ALL FRIEZE BOARDS 8) MISSED 4' JOINT ROOF NAIL GARAGE |