Permit: T09CM02956

Parcel: 13424436A


Addresses:

6301 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM02956

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/06/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/03/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) PROVIDE MINIMUM RED LINES OF WATER SYSTEM WITH CORRECT BACKFLOW PROTECTION REQUIRED 009 OR EQUAL FOR HIGH HAZARD
2) PROVIDE TEST ON VENDING LAUNDRY
07/09/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) THIS INSPECTION FOR 4" AREA DRAIN FROM DETAIL AREA TO INTERCEPTOR ? WATER TEST WITH CLEANOUTS AND VENT TO 10 DEGREES
07/01/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV WATER TEST RESTROOM AND MOP SINK
2) THRU ROOF WATER DISTRIBUTION SAME AREA OK PER RED LINE ON SITE
06/29/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER CONTRACTOR
06/08/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/18/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV & WATER TO ABOVE CEILING FOR DRINKING FOUNTAIN IN WALL