Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM02946

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/14/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/02/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) GAS PRESSURE TEST OK
08/25/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) 2" TIE IN, WATER PIPING OVER HEAD TO HBS, SUPPORTS ON VENT OK
08/18/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PVC TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES THEN NO MORE THAN 4' BETWEEN HANGERS
2) SUPPORT HORIZONTAL PIPING IN THE WALLS AND ISOLATE PVC FROM METAL STUDS
08/16/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ONLY 1/3 OF TOTAL DEVELOPED LENGTH OF A VENT MAY BE RAN IN THE HORIZONTAL POSITION
OK TO COVER WALLS