Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
01/05/2010 BUILDING - FINAL Approved IVRS - Inspection :*
11/06/2009 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE TAPE FROM BOTTOM OF B-VENT ON WATER HEATER
2) FLEX PIPE IS NOT ALLOWED IN TPR DRAIN LINE
3) MINI SPLIT A/C UNIT IS OVERFUSED
4) NEED LADDER TO ACCESS ROOF MOUNTED A/C
5) THE 17' X 17' SOUTHEASE CORNER ROOM, WHICH APPEARS TO BE AN ILLEGAL ENCLOSURE, HAS NO NATURAL LIGHT AND VENTILATION AND NO WALL OUTLETS PER CODE