Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T09CM02921
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/11/2013 | ELECTRIC - INTERMEDIATE | Approved | ||
| 06/11/2010 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 06/08/2010 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) BARN WALLS OK (ONLY) |
|
| 12/15/2009 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUNDS AND NEUTRALS TO BE SEPERATE AT PANEL 2) EXPOSE GROUNDING ELECTRODE SYSTEM AT MARE MOTEL 3) GROUNDING ELECTRODE UFER AT BARN WAS DENIED ON 7/2/09 4) REMOVE COVER AT 400 AMP PANEL 5) MARK SERVICE DISCONNECTS AND INDICATE WHAT IS SERVED BY |