Permit: T09CM02908

Parcel: 110053590


Addresses:

4566 E PATRICIA ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09CM02908

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/18/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
12/03/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
EXTERIOR ELECTRICAL OUTLETS REQUIRE GFCI PROTECTION. DID YOU OBTAIN AN ELECTRICAL WIRING PERMIT AND HAVE THIS NEW ELECTRICAL WIRING INSPECTED.

AN IRON PIPE THREAD CAP IS NOT APPROPRIATE FOR A FLARED FLEX ADAPTOR.
CAP PIPING AS PREVIOUSLY NOTED.
T&P PIPING SHOULD ALSO BE CAPPED.
NEW HEAT PUMP REQUIRES PERMIT AND INSPECTIONS
11/30/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PERMANENTLY CAP OLD WATER HEATER GAS PIPING
2) SECURE THE WEATHER PROOF ENCLOSURE TO STRUCTURE
3) PLEASE READ AND PROVIDE INSTALLATION INSTRUCTIONS FOR INSULATION BEING USED, MOST ARMAFLEX STYLE INSULATION REQUIRE PROTECTION FROM SUN EXPOSURE WITH A TYPE OF PAINT MATERIAL FROM MANUFACTURE