Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 03/04/2010 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SAN TEE NOT ALLOWED IN HORIZONTAL 2) MAKE ALL CONNECTION TO EXISTING SEWER 3) 10' HIGH WATER TEST REQUIRED |