Permit: T09CM02836

Parcel: 11012094A


Addresses:

5301 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM02836

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/02/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/20/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
12/10/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CLOSET FLANGES OK
12/06/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/03/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
12/02/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) NEED TO INSPECT ABOVE CEILING PRIOR TO TILES
11/30/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/29/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/24/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/23/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ROOM 13984 OK
2) CLOSET FLANGES AREA A OK
3) DOMESTIC WATER IN PENT HOUSE OK, JUST NEED RP CERT AT FINAL WITH COMPLETION OF DRAIN AND PIPE INSULATION
11/22/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/19/2010 PLUMBING - INTERMEDIATE Partial Approval AREA A RADIUS WEST OF W/ PC; CLOSET FLANGES OK
11/18/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
11/17/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PIPE INSULATION IN WALLS OK TO COVER
2) CLOSET FLANGES SHALL BE SECURED TO FINISHED FLOOR
11/16/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DOMESTIC WATER IN PENTHOUSE AND ROOMS 10119 AND 10121 OK FOR INSULATION
2) FS IN 13984 OK TO COVER
3) NEED FLASHINGS ON VTRS AT AREA C
11/15/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) MED GAS TEST CHECKED BY THIRD PARTY INSPECTOR
2) PLUMBING NOT READY
11/12/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
11/10/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO INSULATE PIPING
2) 2 INSTALLERS AT NEW ZONE VALVE CORR 13413
11/09/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV AND DOMESTIC WITH TEST AT PATIENT ROOM 20 AND ISOLATION #13 OK
2) SHOWER VALVE REPLACEMENTS AREA C AND AREA D SOUTH OF COL. R OK TO INSULATE
3) SOUTH OF COL. R OK TO INSULATE
11/03/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) AREA C PIPE INSULATION IN WALLS AND TEST FITTINGS PLUGGED
2) OK TO COVER PLUMBING
3) 24 HR LOW PSI TEST ON OUTLET CONNECTIONS OK
4) NEW ZONE PIPING IN PROGRESS AT AREA A/B
11/02/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) AREA C DOMESTIC WATER TEST OK
2) TEST TEE PLUGS IN PLACE
11/01/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV AREA C MATCH LINE TO COL. MR AND COL 19-M10-REPLACING ZONE VALVE
10/29/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) AREA C OVERHEAD WATER OK
2) WALLS ROOMS #10138,10137,10135 PSI TEST OK, 10131-10134
10/28/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/26/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) TOILET ROOMS 10121, 10119A AND 11607 ROUGH SOIL OK
2) SEC A PIPE INSULATION PROGRESS GOOD, SAFETY PLATES ETC..
3) STAFF TOILET 15030 TEST OK
10/25/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) NURSES STATION SINK, PHARMACY, CONFERENCE, CHILD LIFE, PLAY AREA, PUBLIC TOILET AND JANITOR SINK
2) DWV AND DOMESTIC WATER OK
10/22/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) AREA 'A'
10/21/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DOMESTIC WATER IN WALLS, AREA A OK TO INSULATE 3" MAIN FROM POC WITH TEST OK
10/20/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/19/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV WITH TEST THRU ROOF, COLS PL-PD TO P9
10/18/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/15/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DOMOSTE W 232 OK
10/14/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/12/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PENTHOUSE FLOOR SINKS AND VTR OK
2) DOMESTIC WATER IN WALL PATIENT ROOMS WEST
10/08/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) MED GAS PROGRESS OK
2) INTERMEDIATE NOT READY
10/07/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) MED GAS PROGRESS
2) RUDY DON'T FORGET TO ADD OVER HEAD HANGERS AS REQUIRED
10/06/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) AREA C WATER PIPING ABOVE CEILING TEST OK UPTO ROOM VAVLES (ONLY)
2) #15062,15061 ANC CORRIDOR #15070 IN WALL WATER PIPING OK (ONLY)
3) ROOF DRAIN #227-234 TEST OK (ONLY)
10/05/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ROOMS #234 & 230 DRAIN TEST OK (ONLY)
2) ROOM #233 THRU 236 CAST IRON THRU ROOF TEST OK
3) MED GAS PIPING ? PURGE OK WORKING ON WST SIDE OF BLDG
10/04/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/30/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) MED GAS OK
2) RESTROOM 44A,43A,42A AND 41A OK TO COVER WALLS AFTER INSULATION
09/28/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) WORKING ON EAST SIDE OF BLDG
2) DONE WORKING FOR DAY MED GAS
09/24/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/23/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) JANITOR 15058, RS 59.60 DWV AND WATER OK
09/22/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV AND DOMESTIC WATER WITH TEST
2) COLS-3/19 OK
3) NEED TO INSPECT SHOWER PAN LINERS AND FLANGES WHEN READY
09/21/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) TRS 127, 128 WALLS OK
2) SAFETY PLATES REQUIRED
08/16/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/11/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) 3" DOMESTIC CW PER REV PR 6 OK
2) SINKS IN ROOM 10946 DWV AND WATER OK
06/02/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ROOM 10942: FS PIPING OK
2) NOTE: FS IS REQUIRED TO BE READILY ACCESSIBLE WITHOUT OPENING ACCESS DOORS
3) AREA C OBSTETRICS DEMO OK-CACTUS MEDICAL VERIFIED
4) AREA A DEMO OK
05/27/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/24/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
PHASE I NEW SINK RM 13950 OK
KEEP OPEN PIPING CAP ON DURING CONSTRUCTION