| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/24/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/22/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REMOVE TAPE FROM VENT JOINTS OF WATER HEATERS, PROVIDE FASTENERS AT VENT JOINTS, VENT TO GO IN UPWARD DIRECTION TO TERMINATION 2) PROVIDE CORRECT DRAINAGE SLOPE ON DRAINAGE TO 2 COMPS OF 3 COMPARTMENT SINK 3) INSTALL GRATE ON FLOOR SINK 4) PROVIDE HAMMER ARRESTORS ON LAUNDRY BOX WATER SUPPLIES 5) COMMERCIAL BLDGS REQUIRE OPEN FRONT TOILET SEATS 6) EXPOSE ALL CLEANOUTS AS REQUIRED 7) PROVIDE EXPANSION TANKS PER PLAN TO WATER HEATERS 8) PROVIDE VACUUM BREAKERS AT HOSE BIBS |