Permit: T09CM02781

Parcel: 13615017B

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/16/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/13/2009 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) CANNOT USE SCREWS INSIDE PLASTIC BOXES FOR MOUNTING. PLASTIC BOXES TO BE SECURED BY ELECTRICAL METHODS
2) NEED MINIMUM 6" OF FREE CONDUCTOR LENGTH AT BOXES
3) USE PROPER BOX FOR TERMINATION OF OVEN POWER NEED CONNECTOR AT BOX. PLAN CALLS FOR #8 CU.
4) REPLACE BOXES WITH MISSING WIRE TABS. ALL OPENINGS TO BE CLOSED
5) NAIL PLATE WIRES IN HOLES LESS THAN 1 1/4" TO FACE OF STUD
6) NEW DRYER CIRCUITS TO BE 4 WIRE CIRCUITS