Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM02767

Parcel: 110120970


Addresses:

2600 N WYATT DR


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T09CM02767

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
12/03/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
12/01/2009 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CORRECTION NOTED ON 11/25 HAS NOT BEEN CORRECTED
2) DRAW STATION AND EXAM 5 CORRECTIONS OK
3) INSULATE AS SPECIFIED ON MP1-D
4) OK TO BURY EXTERIOR DRAIN FOR EXAM 5
11/30/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) DWVC NOT UNDER TEST AT P-1 EXAM ROOM 5
2) ISOLATE COPPER FROM C1 AT P-1 DRAIN STATION
3) OK TO INSULATE HW PIPING
11/25/2009 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REDUCING MISSION COUPLING ON HORIZONTAL CREATES A LEDGE AND IS NOT APPROVED
2) PROVIDE A TAPPERED FITTING
3) CAST IRON SPECIFIED ABOVE SLAB