Permit: T09CM02760

Parcel: 133383790

Inspection Status: Not Applicable

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/23/2009 PLUMBING - INTERMEDIATE Not Applicable IVRS - Inspection :*
10/26/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/19/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
GAS WATERHEATER INSTALLED W/OUT PERMIT REQUIRES PROPER T & P ROLLOF DRAIN, GAS APPROVED SHUT OFF VALVE & NOW FLEX SURFACE JOINTS OF VENT CONNECTOR.
EXPANSION TANK REQUIRES AT MIN. DUCT STRAPPING OR PIPE CLAMP FOR SUPPORT
CAP SOLAR ROCIRC DRAIN VALVES FOR SAFETY. 160 WILL BURN YOU FAST. PLAN INDICATES A GARAGE DOWN STREAM OF MV. ALSO, THE PIPING PLANS PROVIDED ARE NOT ACCURATE AND THIS INSTALLATION DOES NOT MATCH. T&P TERMINATION IS 6" -24" -V GRADE, SUPPORT PIPING AND COILING NOT ----6'. SEAT ARMORFLEX JOINTS BE MANUFACTURER.