Inspection History Details
Inspection Status: Not Applicable
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/23/2009 | PLUMBING - INTERMEDIATE | Not Applicable | IVRS - Inspection :* | |
| 10/26/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/19/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* GAS WATERHEATER INSTALLED W/OUT PERMIT REQUIRES PROPER T & P ROLLOF DRAIN, GAS APPROVED SHUT OFF VALVE & NOW FLEX SURFACE JOINTS OF VENT CONNECTOR. EXPANSION TANK REQUIRES AT MIN. DUCT STRAPPING OR PIPE CLAMP FOR SUPPORT CAP SOLAR ROCIRC DRAIN VALVES FOR SAFETY. 160 WILL BURN YOU FAST. PLAN INDICATES A GARAGE DOWN STREAM OF MV. ALSO, THE PIPING PLANS PROVIDED ARE NOT ACCURATE AND THIS INSTALLATION DOES NOT MATCH. T&P TERMINATION IS 6" -24" -V GRADE, SUPPORT PIPING AND COILING NOT ----6'. SEAT ARMORFLEX JOINTS BE MANUFACTURER. |