Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2010 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 12/07/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) EXCEPT FOR PORCH COLUMN 2) FTG FOR FUTURE FIREPLACE AT NORTH EAST CORNER NUMBER 5'S AT 8" ON CENTER 3) OK TO POUR |
|
| 12/04/2009 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SITE PLAN CALLS FOR 6'-9" SETBACKS ON ALL FOUR SIDES, FOUND TWO P. PINS ON EAST SIDE ONLY CANNOT USE FENCES FOR PROPERTY LINES 2) LARAGE REBAR MAT N/E CORNER NOT ON PLAN 3) VERT REBARS REQUIRED AT EACH SIDE OF ALL DOORS AND WINDOWS 4) QUES. DO YOU HAVE ENOUGH FALL FOR SEWER ? |