Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09CM02750
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/24/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
11/13/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) THE DISCONNECTING MEANS YOU INSTALLED IS NOT AN APPROVED METHOD. THE DISCONNECTING MEANS IS A LOCK OUT DEVICE THAT GOES IN BEHIND THE FALSE FRONT OF THE BREAKER PANEL AND IS NOT REMOVABLE. YOU INSTALLED SOMETHING THAT IS REMOVEABLE |
|
11/04/2009 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A PERMANENT CAP FOR UNUSED VENT FROM REMOVED GAS WATER HEATER VENT CONNECTION 2) PLEASE INSTALL BONDING CLAMP TO COLD SIDE OF WATER PIPING AFTER CLEANING PIPE OFF 3) PROVIDE FULL SIZE PRESSURE RELIEF DRAIN PIPING IT CANNOT BE REDUCED IN SIZE AND SHALL TERMINATE 6"-24" FROM FINISH GRADE 4) PROVIDE A MEANS FOR DISCONNECT FOR ELECTRICAL TO NEW ELECTRICAL WATER HEATER OR AN APPROVED LOCK OUT MEANS AT BREAKER PANEL 5) IN THE FUTURE CALL IN ALL INSPECTIONS ON YOUR PERMIT CARD AND IF YOU INSTALL NEW ELECTRICAL CIRCUITS YOU NEED ELECTRICAL INSPECTION |