Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T09CM02702
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/09/2009 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BEARING REAR 1/2 TRUSS OVER BAY 2) EDGE NAILING 2 X 4 LEDGER ROOF 3) TRUSS/PLYWOOD BETWEEN MSTR AND HALL BEDROOM GRADE CHANGE 4) NAIL ALL 2ND FLOOR PLATES PER SCHEDULE 5) DBL STUB AND BLOCK BETWEEN FLOOR AT STAIR HEADER 6) FRONT ROOF 1/2 TRUSS BEARING ? 7) 14/SD3 EAST SIDE OF GARAGE TRUSS BOTTOM CHORD TO DBL TOP PLATE |
|
| 12/07/2009 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |