Permit: T09CM02678

Parcel: 130140260


Addresses:

4082 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T09CM02678

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/21/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/20/2010 PLUMBING - INTERMEDIATE Partial Approval EXPOSE ALL CLOSET FLANGES PER 1/11/10 INSPECTION REQUEST
01/11/2010 PLUMBING - INTERMEDIATE Partial Approval 1) WATER TEST DWV AT BREAKROOM SINK AND H20 PIPING OK
2) NEED TO SEE CLOSET FLANGE INSTALLATION PRIOR TO SETING STOOLS
01/07/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE LONG RADIUS DRAWING FITTINGS FOR HORIZONTAL CHANGE OF DIRECTION AT LAVS & AT BREAK ROOM SINK AND RETEST.
11/24/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE APPROVED DRAINAGE FITTINGS, SUPPORT OVERHADE PIPING AT CORRECT INTERVALS. INSTALL PER APPROVED PLAN OR MINIMUM RED LINE ALL CHANGES, PROVIDE WATER HAMMER ARRESTORS FOR QUICK CLOSING VALVES
2) PROVIDE DRAINAGE FITTING FOR URINAL
3) HAVE A PLUMBER ON SITE FOR NEXT INSPECTION OR YOU WILL BE REFEE'D