Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2010 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection :* | |
| 04/19/2010 | PLUMBING - ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNBOLT UPPER CLAMPING RING, EXTEND WATER PROOFING MATERIAL ON TO LOWER FLANGE, THEN REINSTALL UPPER FLANGE 2) A FIBER GLASS MESH IS REQUIRED TO PREVENT CRACKING BETWEEN CAST IRON AND CONCRETE. SEE ILLUSTRATION PROVIDED |
|
| 04/16/2010 | PLUMBING - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) ABOVE CEILING OK TO COVER LABLES OK 2) SEAL TILE LINED SHOWER TO LOWER FHA FLANGE, EXPOSE WEEP HOLES |
|
| 04/12/2010 | PLUMBING - ABOVE CEILING | Partial Approval | IVRS - Inspection :* NON OPERATING CEILINGS OK |
|
| 04/09/2010 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* 1) PROTECT PEX FROM METAL 2) COMPLETE PIPE INSULATION |
|
| 03/22/2010 | PLUMBING - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
| 03/18/2010 | PLUMBING - ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/17/2010 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* | |
| 03/09/2010 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* | |
| 03/08/2010 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* |