Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T09CM02664

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/20/2010 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
1) REVISE PLANS TO SHOW THE ACTUAL DUCT SYSTEM INSTALLED
2) SHOW HOW RETURN AIR ON 1ST FLOOR WILL BE TERMINATED
3) LEAVE OFF SHEETROCK 2ND FLOOR EXHAUST TERMINATION
04/07/2010 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
SEAL ALL JOINTS ON METAL DUCTING. 1ST FLOOR DUCTING REQUIRE MIN R 4.2 INSULATION. ROOFTOP DUCTING REQUIRES MIN R8 ALL DUCT TAPE TO BE UL 181 LISTED TAPE. PROVIDE PANDUIT STRAPS AT ALL FLEX DUCT CONNECTIONS. INSTALL BATHROOM EXHAUST DUCTS.
REVISE PLANS IF CHANGING EQUIPMENT.
INSTALL REFER LINE SETS. INSULATE PER NOTE 2.10 M-2
04/06/2010 MECHANICAL - INTERMEDIATE Cancelled CANCELLED PER CONTRACTOR JASON #445-0762
04/06/2010 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/05/2010 MECHANICAL - INTERMEDIATE Cancelled CANCELLED PER CONTRACTOR JASON #445-0762
04/05/2010 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED