Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T09CM02664

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/08/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
07/02/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SUPPORT SOLAR PIPING ON ROOF AND COMPLETE INSULATION ON ALL HOT AND HOT RETURN PIPING. NOTE: INSULATION EXPOSED TO SUNLIGHT ? PROTECTION FROM SUNLIGHT (PAINT)
2) REMOVE HANDLE OR PROVIDE HOSE BIB CAP ON SOLAR LOOP HOSE BIB TO PREVENT SCALDING
3) PROVIDE SIGNAGE IN ELECTRICAL PANEL NON-BONDED, NON METALIC BLDG WATER PIPING
4) SEE NOTE #1.09 ON PAGE P2 AND PROVIDE STERILIZATION PROCEDURE USED IN WRITING WITH BACTERIA REPORT FROM WATER SAMPLE ? TO INDEPENDENT TESTING AGENCY
5) MAKIE UP STAIRS STOVE WATER TIGHT AT FLOOR