Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T09CM02664
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/08/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
07/02/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SUPPORT SOLAR PIPING ON ROOF AND COMPLETE INSULATION ON ALL HOT AND HOT RETURN PIPING. NOTE: INSULATION EXPOSED TO SUNLIGHT ? PROTECTION FROM SUNLIGHT (PAINT) 2) REMOVE HANDLE OR PROVIDE HOSE BIB CAP ON SOLAR LOOP HOSE BIB TO PREVENT SCALDING 3) PROVIDE SIGNAGE IN ELECTRICAL PANEL NON-BONDED, NON METALIC BLDG WATER PIPING 4) SEE NOTE #1.09 ON PAGE P2 AND PROVIDE STERILIZATION PROCEDURE USED IN WRITING WITH BACTERIA REPORT FROM WATER SAMPLE ? TO INDEPENDENT TESTING AGENCY 5) MAKIE UP STAIRS STOVE WATER TIGHT AT FLOOR |