Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM02636

Parcel: 141312350


Addresses:

9046 S SILKWOOD LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM02636

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/23/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/02/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) MISSED TWO TRUSS HANGERS ROOF CO2 TRUSSES ATTACHED TO GIRDER
2) NAIL END OF FLAT HIP TRUSS AT RIDGE
3) WILL CHECK AT INTERMEDIATE INSPECTION
4) TWO VERT BLOCKS FOR 3 PT BETWEEN FLOORS
5) WILL CHECK AT NEXT INSPECTION
10/30/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NEED DBL HANGER FOR GIRDER TRUSS MG08
2) SOLID BLOCKS VERT ALL LOAD PTS FROM ROOF TO CONC. (3 PT GIRDER NEXT TO STAIR)
3) SEE HENRY, IF AN SOLUTION TO BROKEN COL FTG/STEMS
4) SHEAR TRANSFER FOR ALL PARALELL SHEARWALLS
5) BLOCKING 4' ON CENTER AT PARALELL FLOOR TRUSS SITUATIONS, FOR DRYWALL NAILING 2/SD2
6) SEE 1/SD2 FOR TIES DRAG TRUSS TO DBL TOP PLATE
7) TIE ALL COLS. TO CONC., STUDS TO BOTTOM PLATE