Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/23/2012 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
10/12/2012 PLUMBING - GAS PRESSURE TEST Denied POST YOUR ADDRESS.
SINGLE WALL VENT CONNECTOR SHALL NOT PASS THUR COILING AND REQUIRES 6" CLEAR. LISTED VENT TOO REQURED. HORIZONTAL BENT REQUIRES SUPPORT. SECURE EACH JOINT. RELIEF VALVE REQUIRES PROPER TERMINATION. PROVIDE ROOF ACCESS TO INPECT VENT TERMINATIONS. LISTED CAP REQUIRED. BOTH WHS REQ CORRECTIONS.
09/29/2009 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*