Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM02584

Parcel: 11103018B


Addresses:

3807 E KLEINDALE RD


Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T09CM02584

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/14/2010 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
12/09/2009 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) COMPLETE CONDENSATE PIPING AT MINI-SPLIT
2) PROVIDE SEISMIC SUPPORT TO STRUCTORE ON ALL REGISTERS AND GRILLS IN T-BAR CEILING
3) PROVIDE OBD'S IN SUPPLY GRILLS PER REGISTER SCHEDULE
4) PROVIDE SADDLE SUPPORTS TO ELEVATE FLEX DUCT OFF OF T-BAR PER DETAILS M-2
5) PROVIDE CLEAR LOCKABLE COVERS ON T-STATS PER SPECS
6) PROVIDE STRUCTURAL SUPPORT AROUND ROOF PENETRATIONS PER PLANS