Permit: T09CM02568

Parcel: 133261700


Addresses:

8109 E COLETTE PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/20/2009 FRAMING Approved IVRS - Inspection :*
11/04/2009 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TRIMMERS AT BEAMS AND GLUE LAMS WHERE NEEDED-2 TRIMMERS WHERE OPENING IS 5' PLUS
2) SHIM TRIMMER/HEADER CONNECTIONS WHERE NEEDED
3) TIGHTEN ANCHOR BOLTS
4) DUCT BOOTS NEED FRAMING ON 3 SIDES
5) STRAP ACROSS TOP PLATE BREAK
6) H2.5 PATIO RAFTERS
7) ADD OUTLET IN SOUTH EAST CORNER OF LOWER SOUTH EAST BED AND DEN
8) NEED WALL UNDER BOTTOM OF UPPER STRINGERS
9) NAIL PROTECT WIRES AND PIPES
10) RE-RUN TPR DRAIN LINE