Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T09CM02557
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/27/2010 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/28/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) BE ADVISED, P-RINGS TO SHALLOW IN SAME LOCATIONS, CODE DOES NOT ALLOW MORE THAN 1/4" GAP-SET BACK, OTHERWISE OK WALLS |
|
| 12/24/2009 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) 12 TIMES DIA. FOR BENDING RADIUS 330.24 NEC 2) MAINTAIN 1 1/4" DISTANCE FROM FACE OF STUD WHEN INSTALLING INSIDE CHANNEL OR RUN CABLE OUTSIDE 300.4 NEC |