Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2010 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 02/01/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE INTERCEPTOR MODEL NUMBER AS A REDLINE ON THE PLANS 2. PROVIDE A TEST ON PIPING INCLUDING INDIRECT DRAIN IN WALL |
|
| 01/27/2010 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) IF GT HAS AN INTEGRAL FLOW CONTROL PROVIDE MODEL NUMBER AND INSTALL PER ROCKFORD INSTRUCTIONS 2) RED LINE ALL CHANGES ON APPROVED PLAN 3) A VENT CONNECTION MUST RISE AT A MINIMUM OF 45 DEGREE SO THAT THE VENT TAKE OFF IS ABOVE THE FLOW LINE 4) SWEEP REQUIRED AT VERTICAL TO HORIZONTAL CHANGE OF DIRECTION 5) INSTALL FOAM WRAPS AND PIPE INSULATION |