Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T09CM02485
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/24/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/23/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DWV IS EMPTY AT LAUNDRY BIB 2) STUD SHOE NEEDS NAILS-NOT SHEETROCK SCREWS |
|
| 11/20/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RE-DO DWV LEAKS IN AND ABOVE GARAGE 2) REMOVE MESH STAPLES BEHIND HOME RUNS 3) FHA STRAP OVER BORE OF ABS HOLE IN POWDER, MASTER LAVS AND STUD SHOES ON STUDS OVERBORE AT W. LAV-MASTER 4) LEAK AT UPPER HALL BATH ? 5) SHIM TRIMMER/HEADER CONNECTION IN SOUTHWEST BED 6) INSTALL BACK FLOW VALVE ON HOSE BIB |