Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2010 | STUCCO MESH | Approved | ||
| 10/19/2009 | STUCCO MESH | Not ready for Inspection | IVRS - Inspection :* 1) HAVE SUPER LOOK AT LATH JOB 2) SECURE WIRE AWAY FROM BUSS BARS 3) LADDER BLOCKS, GARAGE TO KIT/BATHROOM, NEED SPACER BLOCKS. BETTER NAILING BLOCK TO TRUSS 4) 2ND FLOOR HALL BATH, TOILET 2" VENT GOING THRU FLOOR SHOULD BE 2-45'S, NOT 2 90'S 5) SECURE ROMEX AT SMART BOX |