Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T09CM02399
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/14/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
09/16/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* KNOW & TUBE WIRING IN BASEMENT HAS OPEN SPLICES AND IN GENERAL IS SUBJECT TO PHYSICAL DAMAGE AND SHOULD BE REPLACED. REPLACE WITH APPROVED WIRING METHON PER NBZ. CONDUITS OUTSIDE WEST WALL NOT SUPPORTED PER CODE (AT SUB PANELS) ALL WIRING TO BE SUPPORTED PER CODE - ROMEX -334 NEC 12" & 4 1/2 " INTERVALS. -LV OR PHONE CABLING IN WORKMAN ? LIKE MANNOR & PER MANUFACTURER. |