Permit: T09CM02345

Parcel: 110100360


Addresses:

4949 E GLENN ST #02

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/21/2009 BUILDING - FINAL Approved IVRS - Inspection :*
09/23/2009 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) TEMPERATURE AND PRESSURE DRAIN PIPING TO BE FULL SIZE (NO FLEX) GRAVITY DRAIN TO DAYLIGHT 6"-24" FROM FINISH GRADE
2) PRESSURE RELIEF ON ROOF TO GRAVITY DRAIN 6"-24" FROM FINISH GRADE SEE 608.4 + 608.5 2006 UPC
3) PLEASE SEE SECTION 414.5 FOR TEMPERATURE CONTROL FOR TUBS NOT TO EXCEED 120 DEGREES. THERE IS A SINGLE HOT CONTROL AT THIS RESIDENCE
4) THERE SHOULD BE A TEMPERING VALVE ON THIS INSTALLATION TO AVOID SCALDING. PLEASE SEE SECTION 101.5.2 FOR SAFETY OF SYSTEMS
5) SECURE AND SUPPORT PIPING FOR SUPPLY FROM PANEL INTO STORAGE TANK. NOTE: ALL CODE SECTIONS FROM 2006 UPC