Permit: T09CM02325

Parcel: 12218450B

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
06/22/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
11/17/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) MAY NOT INTERMINGLE ABS AND PVC
2) AFTER INSTALLING GREEN TRACER, OK TO COVER UNDERGROUND
3) GAS PRESSURE TEST OK
4) OK TO COVER WALLS SUBJECT TO APPROVAL OF PEX IN LIEU OF COPPER