11/09/2009 BUILDING - FINAL Approved IVRS - Inspection :*
11/06/2009 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) LISTING ON <D> BREAKER 30 AMP LARGEST WIRE #8 CU #6 AL INSTALLED
2) RAISE DISHWASHER LINE LOOP MIN. 32" ABOVE F.F. DRAIN BOARD
11/05/2009 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSIDE SERVICE PANEL NO #10 CU TO #6 AL, NEED CO-AL CONNECTOR, WIRE NUT NOT APPROVED, DISSIMILAR METAL
2) RAISE DISHWASHER LINE
3) DEAD SHORT IN WASHER CIRCUIT, BREAKER WON'T RESET
4) ATTIC FURNACE LABEL-NOT MARKED, FLEX AT ATTIC DISCONNECT NOT SECURED AT BOX