Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T09CM02275
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/09/2009 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/06/2009 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) LISTING ON <D> BREAKER 30 AMP LARGEST WIRE #8 CU #6 AL INSTALLED 2) RAISE DISHWASHER LINE LOOP MIN. 32" ABOVE F.F. DRAIN BOARD |
|
| 11/05/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSIDE SERVICE PANEL NO #10 CU TO #6 AL, NEED CO-AL CONNECTOR, WIRE NUT NOT APPROVED, DISSIMILAR METAL 2) RAISE DISHWASHER LINE 3) DEAD SHORT IN WASHER CIRCUIT, BREAKER WON'T RESET 4) ATTIC FURNACE LABEL-NOT MARKED, FLEX AT ATTIC DISCONNECT NOT SECURED AT BOX |