Permit: T09CM02254

Parcel: 134172230


Addresses:

602 S MARVIN AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/16/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/24/2009 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A TRAP ON CONDENSATE DRAIN LINE
2) PROVIDE A SECONDARY OVERFLOW SENSOR
3) PRIMARY DRAIN IS CONNECTED TO SECONDARY OUTLET ON COIL
4) PLASTIC CONDENSATE PUMP NOT ALLOWED IN A RETURN PLENIUM
5) PROPERLY SECURE THE DRAIN LINE FROM THE PUMP
6) DO NOT USE PLASTIC HOSE OUTDOORS
7) TERMINATE WITH APPROVED METHODS
8) REMOVE ALL FOIL TAPE FROM THE VENT CONNECTOR
9) PROVIDE A ROMEX CONNECTOR FOR POWER CORD TO FURNACE
10) USE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE
11) PROPERLY SUPPORT THE ELECTRIC DISCONNECT
12) REPAIR ELECTRIC CONDUIT
13) PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF
14) ID CIRCUIT BREAKER