Permit: T09CM02223

Parcel: 141313540

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T09CM02223

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/27/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/26/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/23/2009 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) SEE #5
10/21/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1. 6"X6" COLUMN CAPS REQ 1/4" OC X 2 1/2" SCREWS PROVIDED BY SIMPSON. LAG SCREWS WILL NOT ACHIEVE THE SAME LOAD VALUE ECCQ66SDS2.5
2. SLOPED HANGER IS AN LSSU210 #10 TECO NAILS-OK (PLEASE LEAVE TRUSS CALC)
3. ELEV 'B' 2ND FLOOR FRONT, SHEAR CONNECTION TO TRUSS (STRUCTUAL TRUSS/USE 7/SD3 TOE NAILS
4. GARAGE TRUSS EAST WALL IS IT A DRAG TRUSS ?
10/19/2009 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) BEARING PT. HEADER OVER STAIRS, BLKS BETWEEN FLR
2) 2ND FLOOR SHEAR, BOTTOM PLATE NAIL PER SCHEDULE #10 SHEAR 16 DIAMETER SINKERS ? ON CENTER
3) ROOF NAILING STAPLES, 3" AT JOINTS, 6" FIELD
4) NAILING HANGERS, AT LIVING ROOM HALF TRUSSES. WHAT IS ID NUMBER FOR THOSE HANGERS, CANNOT FIND ON THAT HANGER ID NUMBER 821 POUNDS
5) IS GABLE TRUSS C37 E A , DRAG TRUSS, OR STRUCTUAL STRUT ?
6) USP KGL T5