Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T09CM02206

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/24/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
08/20/2009 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN OUTLET.
PROVIDE A ROMEX CONNECTOR AT CONNECTION TO FURNACE.
USE PURPLE PRIMER PRIOR TO GLUEING PVC FITTINGS
EXPOSED WIRING OUTDOORS MUST BE PROTECTED FROM DAMAGE. USE CONDUIT
DO NOT USE DUCT TAPE OUTDOORS
CIRCUIT BREAKER TOO SMALL FOR CONDENSON
SEAL AROUND REFER LINE PENETRATION THROUGH EAVE
ISOLATE STEEL STRAP FROM CONTACTING COPPER LINE SET
CONDENSATE CANNOT TERMINATE INTO A SEWER VENT
REPLACE DRILLED SECTION OF VENTS PIPE - TERMENATE TO DIRT
SUPPORT COPPER LINE EVERY 6"