Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2009 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/20/2009 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN OUTLET. PROVIDE A ROMEX CONNECTOR AT CONNECTION TO FURNACE. USE PURPLE PRIMER PRIOR TO GLUEING PVC FITTINGS EXPOSED WIRING OUTDOORS MUST BE PROTECTED FROM DAMAGE. USE CONDUIT DO NOT USE DUCT TAPE OUTDOORS CIRCUIT BREAKER TOO SMALL FOR CONDENSON SEAL AROUND REFER LINE PENETRATION THROUGH EAVE ISOLATE STEEL STRAP FROM CONTACTING COPPER LINE SET CONDENSATE CANNOT TERMINATE INTO A SEWER VENT REPLACE DRILLED SECTION OF VENTS PIPE - TERMENATE TO DIRT SUPPORT COPPER LINE EVERY 6" |