Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09CM02202

Parcel: 126161800

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
12/04/2009 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
1) ADD #4'S VERTS AT 24" ON CENTER TO TIE INTO SLAB AT PRE-SLAB 8/D-1
12/03/2009 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SEE PLANS, FOLLOW ALL DETAILS ON D-1 PAGE, TOE DOWN AT EXISTING WALL, ENTRY DETAIL FRONT, ETC
2. DOOR & WINDOW NEED VERT ON EAST SIDE OF OPENING
3. ALL HORIZONTAL BAR LAPS 20"